The HEX1 and HEX2 switches are decided based on the following rule that combines the converter information and switching frequency information into one Hex code:

2^(TypeNum) x (Fsw,H-bridge + Fsw,boost)

For example for SIRIUS S with type number=10:

2^(10) x (6500+13000)=2.00E+7 (rounded up)

Hex 2 is defined by the decade (=7), Hex 1 by the first digits. i.e. 2.00. From the table in Olivier’s document (attached) we can choose the Hex1 that is the number just before 200, i.e. 177 corresponding to Hex1 is 4. Therefore, the Hex1,2 combination is 4,7. You can find attached the excel file with different cases.

In the future converter types, the type number may be selected based on this rule to avoid any overlapping.

This change is to be made in DSP version 151.

THe DIM number 10 on the DSP Regulation card will display the ERROR.

Convertisseurtype(M+C+D+U)typefHBridgefBoost(M+C+D+U)type(fHBridge+fBoost)Hex1Hex2
BSWSirius 2P1381922.00E+041.30E+042.70E+0868
1
Apolo SingleApolo Single01650006.50E+03133
Apolo 2SApolo 2S12650001.30E+0414
Apolo 4SApolo 4S24650002.60E+0464
Apolo 2PApolo 2P38650005.20E+04114
Apolo 4PApolo 4P416650001.04E+0505
Apolo 2PS2PApolo 2PS2P532650002.08E+0555
1
Sirius Single 1010246500130002.00E+0747
Sirius 2S 1120486500130003.99E+0797
Sirius 4S 1240966500130007.99E+07147
Sirius 2P 1381926500130001.60E+0838
Sirius 4P 14163846500130003.19E+0888
Sirius 2PS2P 15327686500130006.39E+08128
AFE Single 301073741824
AFE 2S 312147483648
AFE 2P 324294967296
Corona S 401.09951E+126500 7.15E+151315
Corona 2S 412.19902E+126500 1.43E+1620
Corona 4S 424.39805E+126500 2.86E+1670
Corona 2P 438.79609E+126500 5.72E+16120
Corona 4P 441.75922E+136500 1.14E+1700
PFW 12500001.00E+0404